Original Articles Open access

Portable central baffle flume

Authors

Published
29 June 2022
Section
Original Articles

Abstract

This paper investigated the hydraulic characteristics of the triangular central baffle (TCB) flume. Laboratory tests were carried out to determine the flume dimensions. The field applicability of the proposed portable device was examined by on-farm installation. According to the laboratory tests, when the contraction ratio, r, was less than 0.39, the flow capacity was not affected by the ratio between the flume’s floor height and the throat width. The laboratory analysis also showed that there was no significant effect of installing an entrance ramp on the stage-discharge relationship for r<0.39, while the entrance ramp increased the discharge capacity for r>0.39. The stage-discharge curve obtained based on the laboratory tests was verified using field data. The results revealed that the proposed portable flume could be used accurately to determine the flow through an unlined ditch. Practical suggestions were proposed to determine the distinguishing condition curve.

References

  1. Barenblatt G.I. 1979. Similarity, self-similarity and intermediate asymptotics. Consultants Bureau, NY, USA. DOI: https://doi.org/10.1007/978-1-4615-8570-1
  2. Barenblatt G.I. 1987. Dimensional analysis. Gordon & Breach, Science Publishers, Amsterdam, The Netherlands.
  3. Bijankhan M., Ferro V. 2019. Experimental study on triangular central baffle flume. Flow Measure. Instrum. 101641. DOI: https://doi.org/10.1016/j.flowmeasinst.2019.101641
  4. Bos M.G. 1989. Discharge measurement structures. International Institute for Land Reclamation and Improvement/ILRI.
  5. De Martino G., Ragone A. 1984. Effects of viscosity and surface tension on slot weirs flow. J. Hydr. Res. 22:327-41. DOI: https://doi.org/10.1080/00221688409499369
  6. Ferro V. 2016. Simple flume with a central baffle. Flow Measure. Instrum. 52:53-6. DOI: https://doi.org/10.1016/j.flowmeasinst.2016.09.006
  7. Ferro V. 2018. Discussion of "Three Simple Flumes for Flow Measurement in Open Channels" by Zohrab Samani. J. Irrig. Drain. Engine. 144:8-9. DOI: https://doi.org/10.1061/(ASCE)IR.1943-4774.0001323
  8. Hager W.H. 1985. Modified venturi channel. J. Irrig. Drain. Engine. 111:19-35. DOI: https://doi.org/10.1061/(ASCE)0733-9437(1985)111:1(19)
  9. Hager W.H. 1989. Mobile flume for circular channel. J. Irrig. Drain. Engine. 114:520-34. DOI: https://doi.org/10.1061/(ASCE)0733-9437(1988)114:3(520)
  10. Kapoor A., Ghare A.D., Vasudeo A.D., Badar A.M. 2019. Channel flow measurement using portable conical central baffle. J. Irrig. Drain. Engine. 145:06019010. DOI: https://doi.org/10.1061/(ASCE)IR.1943-4774.0001427
  11. Lotfi Kolavani F., Bijankhan M., Di Stefano C., Ferro V., Mazdeh A.M. 2019. Experimental study of central baffle flume. J. Irrig. Drain. Engine. 145(3). DOI: https://doi.org/10.1061/(ASCE)IR.1943-4774.0001370
  12. Peruginelli A., Bonacci F. 1995. Funzionamento libero e sommerso di un misuratore di portata a risalto idraulico. Idrotecnica. Sept-Dec:261-72 [In Italian].
  13. Samani Z. 2017. Three simple flumes for flow measurement in open channels. J. Irrig. Drain. Engine. 143:2-5. DOI: https://doi.org/10.1061/(ASCE)IR.1943-4774.0001168
  14. Samani Z., Jorat S., Yousef M. 1991. Hydraulic characteristics of circular flume. J. Irrig. Drain. Engine. 117:558-66. DOI: https://doi.org/10.1061/(ASCE)0733-9437(1991)117:4(558)
  15. Sargison E.J. 1972. The influence of surface tension on weir flow. J. Hydr. Res. 10:431-46. DOI: https://doi.org/10.1080/00221687209500034
  16. Ranga Raju K.G., Asawa G.L. 1977. Viscosity and surface tension effects on weir flow. J. Hydr. Division ASCE. 103:1227-31. DOI: https://doi.org/10.1061/JYCEAJ.0004857
  17. Rao S.S., Shukla M.J. 1971. Characteristics of flow over weirs of finite crest width. J. Hydr. Division ASCE. 97:1807-16. DOI: https://doi.org/10.1061/JYCEAJ.0003138

Metrics