Portable central baffle flume

Submitted: 5 January 2022
Accepted: 21 April 2022
Published: 29 June 2022
Abstract Views: 592
PDF: 257
HTML: 48
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

This paper investigated the hydraulic characteristics of the triangular central baffle (TCB) flume. Laboratory tests were carried out to determine the flume dimensions. The field applicability of the proposed portable device was examined by on-farm installation. According to the laboratory tests, when the contraction ratio, r, was less than 0.39, the flow capacity was not affected by the ratio between the flume’s floor height and the throat width. The laboratory analysis also showed that there was no significant effect of installing an entrance ramp on the stage-discharge relationship for r<0.39, while the entrance ramp increased the discharge capacity for r>0.39. The stage-discharge curve obtained based on the laboratory tests was verified using field data. The results revealed that the proposed portable flume could be used accurately to determine the flow through an unlined ditch. Practical suggestions were proposed to determine the distinguishing condition curve.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

Barenblatt G.I. 1979. Similarity, self-similarity and intermediate asymptotics. Consultants Bureau, NY, USA. DOI: https://doi.org/10.1007/978-1-4615-8570-1
Barenblatt G.I. 1987. Dimensional analysis. Gordon & Breach, Science Publishers, Amsterdam, The Netherlands.
Bijankhan M., Ferro V. 2019. Experimental study on triangular central baffle flume. Flow Measure. Instrum. 101641. DOI: https://doi.org/10.1016/j.flowmeasinst.2019.101641
Bos M.G. 1989. Discharge measurement structures. International Institute for Land Reclamation and Improvement/ILRI.
De Martino G., Ragone A. 1984. Effects of viscosity and surface tension on slot weirs flow. J. Hydr. Res. 22:327-41. DOI: https://doi.org/10.1080/00221688409499369
Ferro V. 2016. Simple flume with a central baffle. Flow Measure. Instrum. 52:53-6. DOI: https://doi.org/10.1016/j.flowmeasinst.2016.09.006
Ferro V. 2018. Discussion of "Three Simple Flumes for Flow Measurement in Open Channels" by Zohrab Samani. J. Irrig. Drain. Engine. 144:8-9. DOI: https://doi.org/10.1061/(ASCE)IR.1943-4774.0001323
Hager W.H. 1985. Modified venturi channel. J. Irrig. Drain. Engine. 111:19-35. DOI: https://doi.org/10.1061/(ASCE)0733-9437(1985)111:1(19)
Hager W.H. 1989. Mobile flume for circular channel. J. Irrig. Drain. Engine. 114:520-34. DOI: https://doi.org/10.1061/(ASCE)0733-9437(1988)114:3(520)
Kapoor A., Ghare A.D., Vasudeo A.D., Badar A.M. 2019. Channel flow measurement using portable conical central baffle. J. Irrig. Drain. Engine. 145:06019010. DOI: https://doi.org/10.1061/(ASCE)IR.1943-4774.0001427
Lotfi Kolavani F., Bijankhan M., Di Stefano C., Ferro V., Mazdeh A.M. 2019. Experimental study of central baffle flume. J. Irrig. Drain. Engine. 145(3). DOI: https://doi.org/10.1061/(ASCE)IR.1943-4774.0001370
Peruginelli A., Bonacci F. 1995. Funzionamento libero e sommerso di un misuratore di portata a risalto idraulico. Idrotecnica. Sept-Dec:261-72 [In Italian].
Samani Z. 2017. Three simple flumes for flow measurement in open channels. J. Irrig. Drain. Engine. 143:2-5. DOI: https://doi.org/10.1061/(ASCE)IR.1943-4774.0001168
Samani Z., Jorat S., Yousef M. 1991. Hydraulic characteristics of circular flume. J. Irrig. Drain. Engine. 117:558-66. DOI: https://doi.org/10.1061/(ASCE)0733-9437(1991)117:4(558)
Sargison E.J. 1972. The influence of surface tension on weir flow. J. Hydr. Res. 10:431-46. DOI: https://doi.org/10.1080/00221687209500034
Ranga Raju K.G., Asawa G.L. 1977. Viscosity and surface tension effects on weir flow. J. Hydr. Division ASCE. 103:1227-31. DOI: https://doi.org/10.1061/JYCEAJ.0004857
Rao S.S., Shukla M.J. 1971. Characteristics of flow over weirs of finite crest width. J. Hydr. Division ASCE. 97:1807-16. DOI: https://doi.org/10.1061/JYCEAJ.0003138

How to Cite

Bijankhan, M., Teymourkhani, A. and Ferro, V. (2022) “Portable central baffle flume”, Journal of Agricultural Engineering, 53(2). doi: 10.4081/jae.2022.1339.